top of page

18.3.4.1. Siemens Profinet

18.3.4.1. Siemens Profinet

  1. GSD file (XML file) importing

Open Siemens programming software TIA Portal V17, create a new PLC project, select ‘Devices and Networks’, and select ‘Hardware Catalogue’ on the right side to add PLC module by double clicking 6ES7 515-2AM02-0AB0 to add PLC module.

In the TIA PORTAL software, select Options-> Manage Generic Station Description File (GSD) in the menu bar to install or remove a GSD file that has already been installed.

As an example, to install the Herschel GSD file, select ‘Manage Generic Station Description File (GSD)’ as above, and the ‘Manage Generic Station Description File’ window will appear.

Select the folder where you want to install the GSD file from the ‘Source Path’, select one or more files to install from the list of displayed GSD files, and click the ‘Install’ button. Click the Install button as shown in the following figure.

After successful installation, you can find the device with the installed GSD file in the hardware catalogue, other field devices, as shown in the figure below.

  1. Executable programme

Open the project ‘QNXtest’.

Compiler: Double-click on the left side of the project tree to enter ‘Devices and Networks’, right-click on the ‘PLC_1’ module, select Compile from the drop-down menu, and then select ‘Hardware and Software (Changes Only)’ from the stand-alone menu. Hardware and Software (Changes Only)’. After the compilation is completed, it will prompt ‘Compilation complete’ at the bottom of the software view.

Download the programme to the device: Double click on the left side of the project tree to enter the ‘Device and Network’, right click on the ‘PLC_1’ module, and select ‘Download to Device’ from the drop-down menu. ‘Download to Device’, “Hardware and Software (change only)”.

Search and download devices: After the pop-up window, configure the PG/PC interface type as shown in the following figure, click Start Search, select the device that needs to download the programme, and click Download.

18.3.4.2. Mitsubishi CC-Link IEF Basic

  1. CC-Link IEF Basic Setup

Enable CC-Link IEF Basic: Select ‘Ethernet Port’ in the left menu bar, set the ip address of PLC and make sure it is in the same network segment as the address of Huexun card. Click ‘CC-Link IEF Basic’ and select ‘Use’.

CC-Link IEF Basic Network Configuration Settings: Also in CC-Link IEF Basic Settings, select ‘Network Configuration Settings’, and choose Hueyoson CIFX Digital I/O module. Drag and drop the module to the bottom left of the view to complete the hardware configuration.

CC-Link IEF Basic Refresh Settings: Also in CC-Link IEF Basic Settings, click Refresh Settings to customise the transmission settings: 256 bytes receive, 256 bytes transmit.

  1. Program Download

After opening the test programme, click ‘Online’->‘Write to Programmable Controller’ to enter the download interface.

After opening the download interface, click ‘Parameter+Programme’ on the top left, then click ‘Execute’ on the bottom right corner to download, wait for the download to complete.


robotic arm
FAIRINO ROBOTIC ARMS

Contact

Location: 10637 Scripps Summit Court,

San Diego, CA. 92131
Phone: (619) 333-FAIR
Email: hello@fairino.us

© 2023 FAIRINO Proudly created By G2T

bottom of page